PORTABLE GENERATORS
The Makinex range of generators covers single and 3 phase requirements and is rated from 6 – 16KVA and 10amp to 32amp capacity. Petrol and diesel (9KVA) models available.
Features and Benefits
-
Galvanized frame for greater durability and ease of cleaning
-
Compact trolley design for greater manoeuvrability and ease of storage
-
Lifting point for safer handling
-
3 year Honda engine and RFL alternator warranty
-
Permanent magnet alternator gives 15% greater efficiency of power and reduces fuel consumption
-
RCBO surge protection for both the machine and the user.
-
RCD earth protection
-
Supply capability of multiple phase circuits with varying loads at same time
Which Generator for What?
6kVA PETROL
2 x 15A Single Phase Sockets
AIRLESS SPRAYERS
CORE DRILL
DEMO SAWS
JACK HAMMERS
PORTABLE SPOTLIGHTS
PREASURE WASHERS
SMALL COMPRESSORS
VACS
10KVA PETROL
2 x 15A Single Phase + 1 x 20A 3 Phase Sockets
AIRLESS SPRAYERS
CORE DRILL
DEMO SAWS
JACK HAMMERS
PORTABLE SPOTLIGHTS
PREASURE WASHERS
SMALL COMPRESSORS
VACS
3 PHASE VACS
3 PHASE FLOOR GRINDERS (less than 22A)
3 PHASE WELDERS (less than 20A)
16KVA PETROL
2 x 15A Single Phase + 1 x 32A 3 Phase Sockets
AIRLESS SPRAYERS
CORE DRILL
DEMO SAWS
JACK HAMMERS
PORTABLE SPOTLIGHTS
PREASURE WASHERS
SMALL COMPRESSORS
VACS
3 PHASE VACS
3 PHASE FLOOR GRINDERS (less than 42A)
3 PHASE WELDERS (less than 32A)
HIGH FREQUENCY SAWS
9KVA DIESEL
2 x 15A Single Phase + 1 x 20A 3 Phase Sockets
*Mine Spec Option Available *
AIRLESS SPRAYERS
CORE DRILL
DEMO SAWS
JACK HAMMERS
PORTABLE SPOTLIGHTS
PREASURE WASHERS
SMALL COMPRESSORS
VACS
3 PHASE VACS
3 PHASE FLOOR GRINDERS (less than 22A)
3 PHASE WELDERS (less than 22A)
HIGH FREQUENCY SAWS
Available Models
GEN-6P
SPECIFICATIONS
Max Output: 6kVA
Frequency: 50Hz
Voltage: 240V
Rated Output: 3840W
Max Output: 4800W
Sockets: 2 x 15A single phase sockets with RCBO protection
Weight: 74kg
Noise Level: (7m) No load - 70DB 50% load - 72dB 100% load - 74dB
Rated Power Factor: 0.8
Engine Type: Single Cylinder Air Cooled Petrol
Model: Honda GX-270
Starting System: Pull Start
Displacement: 265cc
Net Power: 4.8 KW @ 3000 rpm
Continuous Power: 3.8 KW @ 3000 rpm
Fuel Economy: 2.1 L/H @ 50% load
Fuel Tank: 5.3L
Dimensions: 515mm(L) x 549mm(W) x 1059mm(H)
Efficiencies: 91.3%
GEN-9D
SPECIFICATIONS
Max Output: 9kVA
Frequency: 50Hz
Voltage: 240V
Rated Output: 6200W
Max Output: 7600W
Sockets: 2 x 15A single phase + 1 x 20A 3 phase sockets with RCBO protection
Weight: 122kg
Noise Level: (7m) No load - 78dB 50% load - 80dB 100% load - 82dB
Rated Power: Factor 0.8
Engine Type: Single Cylinder, Direct Injection Diesel
Starting System: Electric /Pull Start
Displacement: 265cc
Net Power: 7.2 KW @ 3000 rpm
Continuous Power: 5.8 KW @ 3000 rpm
Fuel Economy: 2.1 L/H @ 50% load
Fuel Tank: 5L
Dimensions: 597mm(L) x 645mm(W) x 1231mm(H)
Efficiencies: 93.5%
GEN-10P
SPECIFICATIONS
Max Output: 10kVA
Frequency: 50Hz
Voltage: 240V
Rated Output: 6400W
Max Output: 8000W
Sockets: 2 x 15A single phase + 1 x 20A 3 phase sockets with RCBO protection
Weight: 100kg
Noise Level: (7m) No load - 72 50% load - 76d B 100% load - 78dB
Rated Power Factor: 0.8
Engine Type: Single Cylinder Air Cooled Petrol
Model: Honda GX-390
Starting System: Pull Start
Displacement: 505cc
Net Power: 7.8 kW @ 3000 rpm
Continuous Power: 6.4 kW @ 3000 rpm
Fuel Economy: 2.4 L/H @ 50% load
Fuel Tank: 6.1 L
Dimensions: 598mm(L) x 609mm(W) x 1162mm(H)
Efficiencies: 93.5%
GEN-16P
SPECIFICATIONS
Max Output: 16kVA
Frequency: 50Hz
Voltage: 240/415V
Rated Output: 10400W
Max Output: 12800W
Sockets: 2x15A single phase + 1 x 20A or 32A 3 Phase Sockets with RCBO protection
Weight: 155kg
Noise level: (7m) No Load - 72dB 50% Load – 76dB 100% Load – 78dB
Rated Power Factor: 0.8
Engine Type: Twin Cylinder Air Cooled Petrol
Model: Honda GX-690
Starting system: Key Start
Displacement: 688cc
Net Power: 12.8 kW @ 3000 rpm
Continuous Power: 10.24 kW @ 3000 rpm
Fuel Economy: 3.5 L/h @ 50% load
Fuel Tank: 34 L
Dimensions: 773mm(L) x 530mm(W) x 902mm(H)
Efficiencies: 95.2%
Makinex generators use RFL altenator technology
SPECIFICATIONS | RF2-12.5-3P | RF2-7.5-2P |
---|---|---|
IMAGE | ||
KW | 8 | 6 |
EFFICIENCY | 92% | 92% |
KVA | 10 | 7.5 |
THD (no load – full load) | less than 3 – less than 1.5 | less than 3 – less than 1.5 |
VOLTAGE REGULATOR | +5% | +5% |